【目的】匝间短路(ITSC)是圆柱式线性感应电磁泵(ALIP)的一种典型故障,危及液态金属冷却介质的传输容量和快堆的散热效能。针对此问题,本文提出一种基于电磁场降阶模型(ROM)与粒子群优化(PSO)算法的ITSC故障反演方法。【方法】以某原型钠介质ALIP为研究对象,搭建故障模拟与漏磁检测平台。通过拉丁超立方采样生成不同故障工况下的样本数据集。采用本征正交分解提取电磁场主导模态及相应模态系数,并结合深度神经网络建立运行工况参数与模态系数之间的非线性映射,构建ALIP电磁场ROM。以外壳空间稀疏磁通测点数据为输入,利用构建的ROM和PSO算法实现ITSC故障的快速重构与辨识。【结果】结果表明,该ROM对外壳漏磁和铁心磁场的计算结果相对全阶模型(FOM)的最大相对误差分别为3.9%和3.5%,计算速度相较FOM提升4 447倍;所提反演方法可准确辨识ITSC故障,单次反演仅耗时12 s。【结论】所提方法为面向数字孪生的ALIP健康管理系统提供了方法支撑,有助于提升设备及新一代核电系统的运行可靠性。
[Key word]
[Abstract]
[Objective] Inter-turn short circuit (ITSC) is a typical fault of the annular linear induction pump (ALIP), which impairs the transport capacity of liquid metal coolant and the heat dissipation performance of fast reactors. To address this issue, this paper proposes an ITSC fault inversion method based on electromagnetic field reduced-order model (ROM) with the particle swarm optimization (PSO) algorithm. [Methods] A prototype sodium-cooled ALIP was taken as the research object, a fault simulation and leakage magnetic field test platform was established. Latin hypercube sampling was adopted to generate sample datasets under various fault conditions. Proper orthogonal decomposition was used to extract the electromagnetic field dominant modes and corresponding mode coefficients. A deep neural network was further combined to establish the nonlinear mapping between operating condition parameters and mode coefficients, and the electromagnetic field ROM of the ALIP was constructed. Taking the sparse magnetic flux measurement data on the pump shell as inputs, the established ROM and the PSO algorithm were utilized to realize the rapid reconstruction and identification of ITSC faults. [Results] The results showed that the maximum relative errors of the ROM-calculated shell leakage magnetic field and core magnetic field against the full-order model (FOM) were 3.9% and 3.5%, respectively, and the computational speed was improved by a factor of 4 447 compared with the FOM. The proposed inversion method could accurately identify ITSC faults, with a single inversion taking only 12 s. [Conclusion] The proposed method provides methodological support for developing digital-twin-oriented ALIP health management systems and facilitates the enhancement of operational reliability for the equipment and new-generation nuclear power systems.
[中图分类号]
[基金项目]
国家国防科技工业局项目(HNKF202305)