Abstract:[Objective] The aviation three-stage generator is the core equipment of the airborne power supply system. The rotating rectifier of the generator operates for extended periods under harsh airborne environments characterized by high temperature, high speed, and intense vibration, making its diodes highly susceptible to open-circuit faults. Once a diode fails open, the rectification path of the corresponding phase is cut off, directly causing distortion of the rectified output voltage waveform and a drop in direct current output voltage. If such a fault is not detected promptly, it will directly endanger flight safety. [Methods] To address the above issues, this paper proposed a fault diagnosis method based on an improved secretary bird optimization algorithm (SBOA) for optimizing variational mode decomposition (VMD), combined with a diagonal structured state space sequence (S4D) model. The improved SBOA was used to adaptively optimize the number of modes K and the bandwidth penalty factor α of VMD. By streamlining the original three-stage hunting strategy of SBOA and introducing a Lévy flight exploration mechanism and an exponential decay contraction mechanism, a balance between global exploration and local exploitation was achieved. Meanwhile, a dual-objective weighted fitness function that balanced decomposition quality and computational efficiency was designed. Firstly, the excitation current signal was preprocessed, and the optimized VMD was adopted to decompose it into several intrinsic mode components. Then, the obtained components were normalized and divided into sliding-window patches. The S4D model was used to learn discriminative energy and temporal features within the components to realize the classification of five types of fault modes. Finally, simulations and experiments were carried out to verify the effectiveness of the proposed method. [Results] The experimental results showed that the proposed method achieved an average diagnosis accuracy of over 98.5% under multiple operating conditions. Compared with traditional methods, it had significant advantages in accuracy and cross-load transfer capability, and maintained stable accuracy especially under high-load conditions. [Conclusion] The improved SBOA-VMD-S4D fault diagnosis method proposed in this paper can effectively separate fault information and exhibits strong classification performance and cross-load generalization capability. It provides an accurate and efficient technical solution for fault diagnosis of rotating rectifiers in three-stage aviation generators.