Abstract:[Objective] The main pump motor of the valve cooling system generally adopts a squirrel-cage asynchronous motor, which is prone to inter-turn short circuit faults during long-term operation. Traditional time-frequency analysis methods struggle to effectively extract and distinguish feature information corresponding to different severity levels of inter-turn short-circuit faults. [Methods] To address this issue, this paper proposed a fault diagnosis method that integrated the discrete wavelet transform (DWT) with the self-attention mechanism. Firstly, inter-phase differentiation was applied to stator three-phase current signals. The channel number was expanded to 6 to incorporate inter-phase unbalance characteristics. Then, the DWT was employed to perform multi-scale frequency-band decomposition on the signals, and linear interpolation was adopted to unify all sub-bands into equal-length Token sequences. Finally, the Token sequences were fed into a Transformer encoder, in which global feature interaction was realized through the multi-head self-attention mechanism, and the classification Token was fused with global average pooling to complete the classification task. Compared with traditional time-frequency analysis methods, the proposed method directly took the 1D frequency bands as input, thereby avoiding the information compression and distortion incurred during 2D image transformation. During the model training and evaluation stages, a 5-fold cross-validation was adopted to eliminate the randomness caused by a single data split and rigorously validate the generalization capability of the proposed method. [Results] To verify the effectiveness of the proposed DWT-Transformer model, it was compared with two models that combine the continuous wavelet transform (CWT) with the vision Transformer (ViT). The experimental results showed that under 5-fold cross-validation, the average test accuracy of the proposed DWT-Transformer model reached 97.57%, which was superior to the two CWT-ViT models. [Conclusion] The combination of DWT multi-scale frequency band decomposition and self-attention mechanism has certain feasibility and effectiveness in the fault diagnosis of motor inter-turn short circuit.