Abstract:[Objective] Aiming at the problem that the speed control system of permanent magnet synchronous motor (PMSM) tends to suffer from increased overshoot and slow disturbance recovery under the conditions of rapid reference speed variation, load disturbance and parameter perturbation, this paper proposes an active damping integral sliding mode control (ADISMC) method based on the nonlinear extended state observer (NLESO). [Methods] This method equivalented the PMSM speed loop to a first-order system with lumped disturbances. The NLESO was used to online estimate the lumped disturbances and speed variation trend. An active damping term consisting of the speed derivative estimated by the NLESO was introduced into the integral sliding mode surface, so that the controller could adjust the sliding mode dynamics in real time according to the speed variation trend. The speed-loop control law was constructed by combining disturbance feedforward compensation and exponential reaching law. Furthermore, the uniformly ultimately boundedness of the sliding mode variable and speed error was proven under the premise that the disturbance estimation error was bounded. [Results] Comparisons between the proposed method and other speed control algorithms were carried out under the constraints of identical sampling period, current limiting and parameter tuning. The Simulink simulations covered various operating conditions: no-load step response, sudden load change, composite speed reference of low speed and forward-reverse rotation, continuous load with current limitation, single-parameter perturbation and simultaneous multi-parameter perturbation. The simulation results showed that the proposed method achieved smaller overshoot and shorter disturbance recovery time under all test conditions. Experimental verifications were implemented on an embedded platform with the VOFA+ host computer. The experimental results demonstrated that the overshoot of the proposed method was 0.46% under the no-load step operating condition; the speed drop was 24.8 r/min and the recovery time was 15 ms under load disturbance operating condition. [Conclusion] These results verify the effectiveness and practical implementability of the proposed method for PMSM speed control.