Abstract:[Objective] Inter-turn short circuit (ITSC) is a typical fault of the annular linear induction pump (ALIP), which impairs the transport capacity of liquid metal coolant and the heat dissipation performance of fast reactors. To address this issue, this paper proposes an ITSC fault inversion method based on electromagnetic field reduced-order model (ROM) with the particle swarm optimization (PSO) algorithm. [Methods] A prototype sodium-cooled ALIP was taken as the research object, a fault simulation and leakage magnetic field test platform was established. Latin hypercube sampling was adopted to generate sample datasets under various fault conditions. Proper orthogonal decomposition was used to extract the electromagnetic field dominant modes and corresponding mode coefficients. A deep neural network was further combined to establish the nonlinear mapping between operating condition parameters and mode coefficients, and the electromagnetic field ROM of the ALIP was constructed. Taking the sparse magnetic flux measurement data on the pump shell as inputs, the established ROM and the PSO algorithm were utilized to realize the rapid reconstruction and identification of ITSC faults. [Results] The results showed that the maximum relative errors of the ROM-calculated shell leakage magnetic field and core magnetic field against the full-order model (FOM) were 3.9% and 3.5%, respectively, and the computational speed was improved by a factor of 4 447 compared with the FOM. The proposed inversion method could accurately identify ITSC faults, with a single inversion taking only 12 s. [Conclusion] The proposed method provides methodological support for developing digital-twin-oriented ALIP health management systems and facilitates the enhancement of operational reliability for the equipment and new-generation nuclear power systems.