Issue 11,2026 Table of Contents

  • Display Type:
  • Text List
  • Abstract List
  • 1  Diagnosis Method for Open-Circuit Faults of Power Switches in Dual Three-Phase PMSM Based on Current Sector Characteristics
    Zhu Xinyi ,  Cui Jiang
    2026(11):1106-1118. DOI: 10.12177/emca.2026.242
    [Abstract](4) [HTML](0) [PDF 747.86 K](0)
    Abstract:
    [Objective] Aiming at the open-circuit fault of inverter power switches in dual three-phase permanent magnet synchronous motor (DTP-PMSM), this paper proposes a fault diagnosis method based on current sector characteristics. [Methods] Taking advantage of the synchronization and symmetry characteristics of the sector-switching process of currents in the two sets of three-phase windings, the sector dwell width of the healthy winding was adopted as an adaptive reference benchmark. A diagnostic variable capable of characterizing winding abnormal states was constructed to realize rapid identification of the faulty winding. On this basis, the current crossing-point information during the sector transition of the healthy winding was extracted to establish an adaptive localization threshold. By counting the number of threshold-crossing points within the half-wave interval of each phase current of the faulty winding, the localization of single-switch open-circuit faults and various types of double-switch open-circuit faults was achieved. Finally, an experimental platform of the DTP-PMSM was built, and experimental verifications were carried out under different open-circuit fault types of power switches as well as dynamic operating conditions including speed and load variations. [Results] Experimental results demonstrated that the proposed method exhibited favorable robustness under multiple fault modes and dynamic operating conditions, together with a fast alarm response. The time interval from fault occurrence to alarm triggering was only half a sector period. [Conclusion] The proposed diagnosis method for open-circuit faults of inverter power switches in DTP-PMSM based on current sector characteristics achieves high diagnostic accuracy, favorable disturbance rejection capability and great potential for engineering applications.
    2  Active Suppression of Torsional Vibration in Motor Dual-Inertia Systems
    Liu Xiong ,  Liu Yuqi ,  Chen Kaihao ,  Liang Zhenhua ,  Deng Hui
    2026(11):1119-1129. DOI: 10.12177/emca.2026.240
    [Abstract](3) [HTML](0) [PDF 609.79 K](1)
    Abstract:
    [Objective] Permanent magnet synchronous motor (PMSM) exhibits high efficiency, high power density and superior dynamic performance, and is widely adopted in high-precision servo control fields. Nevertheless, servo systems are plagued by mechanical torsional vibration arising from elastic shaft coupling in practical scenarios. Traditional proportional-integral (PI) control cannot strike a favorable balance between fast dynamic response and torsional vibration suppression. [Methods] To address this issue, this paper introduced model predictive control (MPC) into the speed control framework of a dual-inertia elastic system of PMSM to replace traditional PI control. Firstly, a mathematical model was established for the dual-inertia elastic transmission system driven by the PMSM, and the speed response and torsional vibration characteristics of the system under PI speed control were analyzed. Then, active damping control with speed difference feedback was adopted to suppress torsional vibration by increasing system damping. However, this method sacrificed the dynamic response performance of the system. To solve this issue, this paper proposed using MPC to replace the PI control of the speed loop. MPC performed rolling optimization based on the system model and featured excellent control performance and strong robustness. Finally, the feasibility of the proposed strategy was verified by simulations and experiments. [Results] The results showed that PI control exhibited obvious oscillations when the system encountered torsional vibration and could hardly meet the requirements of high-precision servo control. Active damping control delivered excellent torsional vibration suppression performance, yet at the cost of partial dynamic response performance. In comparison, although MPC was slightly inferior to active damping control in suppressing torsional vibration, it could still achieve favorable suppression effects and features superior dynamic speed response. [Conclusion] The strategy of using MPC to replace the speed loop PI control can effectively suppress torsional vibration and exhibits favorable feasible. Compared with the traditional active damping method, this approach can balance fast dynamic response and torsional vibration suppression, holding broad application prospects.
    3  Fault Diagnosis Technology for Rotating Rectifiers in Aviation Three-Stage Generators Based on Improved SBOA-VMD-S4D
    Chen Qiyuan ,  Cui Jiang
    2026(11):1130-1144. DOI: 10.12177/emca.2026.241
    [Abstract](3) [HTML](0) [PDF 670.11 K](0)
    Abstract:
    [Objective] The aviation three-stage generator is the core equipment of the airborne power supply system. The rotating rectifier of the generator operates for extended periods under harsh airborne environments characterized by high temperature, high speed, and intense vibration, making its diodes highly susceptible to open-circuit faults. Once a diode fails open, the rectification path of the corresponding phase is cut off, directly causing distortion of the rectified output voltage waveform and a drop in direct current output voltage. If such a fault is not detected promptly, it will directly endanger flight safety. [Methods] To address the above issues, this paper proposed a fault diagnosis method based on an improved secretary bird optimization algorithm (SBOA) for optimizing variational mode decomposition (VMD), combined with a diagonal structured state space sequence (S4D) model. The improved SBOA was used to adaptively optimize the number of modes K and the bandwidth penalty factor α of VMD. By streamlining the original three-stage hunting strategy of SBOA and introducing a Lévy flight exploration mechanism and an exponential decay contraction mechanism, a balance between global exploration and local exploitation was achieved. Meanwhile, a dual-objective weighted fitness function that balanced decomposition quality and computational efficiency was designed. Firstly, the excitation current signal was preprocessed, and the optimized VMD was adopted to decompose it into several intrinsic mode components. Then, the obtained components were normalized and divided into sliding-window patches. The S4D model was used to learn discriminative energy and temporal features within the components to realize the classification of five types of fault modes. Finally, simulations and experiments were carried out to verify the effectiveness of the proposed method. [Results] The experimental results showed that the proposed method achieved an average diagnosis accuracy of over 98.5% under multiple operating conditions. Compared with traditional methods, it had significant advantages in accuracy and cross-load transfer capability, and maintained stable accuracy especially under high-load conditions. [Conclusion] The improved SBOA-VMD-S4D fault diagnosis method proposed in this paper can effectively separate fault information and exhibits strong classification performance and cross-load generalization capability. It provides an accurate and efficient technical solution for fault diagnosis of rotating rectifiers in three-stage aviation generators.
    4  High-Speed BLDCM Commutation Correction Control Based on FWE-QPLL Phase Extraction
    Yan Jingxue ,  Wang Yuan ,  Li Hui
    2026(11):1145-1155. DOI: 10.12177/emca.2026.245
    [Abstract](3) [HTML](0) [PDF 675.97 K](1)
    Abstract:
    [Objective] In the sensorless control of high-speed brushless direct current motor (BLDCM), commutation errors are susceptible to filter delay, execution delay and current phase lag, resulting in increased current peak values, asymmetric current waveforms, aggravated torque ripple and degraded system stability. Especially under high-speed operation and prominent harmonic interference, the detection of commutation characteristic quantities and phase extraction tend to introduce extra errors, which further deteriorate the accuracy of commutation control. To address this problem, this paper proposes a commutation error correction method based on fundamental wave extraction (FWE) and dual-channel quadrature phase-locked-loop (QPLL). [Methods] Firstly, a permanent magnet flux linkage observer was constructed to reconstruct the permanent magnet flux linkage vector and obtain the rotor electrical angle and speed, which provided rotor position information for sensorless commutation. Secondly, the FWE was adopted to extract the fundamental waves of the flux linkage and integrated phase current signals and suppress the interference of harmonic components on phase extraction. Subsequently, the two fundamental wave signals were normalized, and two independent QPLL were used to track the phases of the two fundamental wave signals, respectively. The dual-channel QPLL were configured with identical natural frequency and damping ratio to guarantee consistent bandwidth and phase delay characteristics, so that additional phase errors introduced by inconsistent dynamic responses of the phase-locked-loop were avoided. Finally, the phase difference between the two fundamental waves was used to characterize the relative phase relationship between the permanent magnet flux linkage and the integrated phase current signals. The commutation error signal was constructed, and the electrical angle was corrected to implement commutation. [Results] A simulation model was built in Matlab/Simulink, and an experimental platform was constructed to verify the proposed method. Simulation and experimental results showed that the proposed method could converge the commutation error to near zero under advanced and delayed commutation conditions and significantly reduce the peak-to-peak phase current. The peak-to-peak phase current was reduced by 42.9% and 56.3% in simulations, and by 10.0% and 18.2% in experiments, respectively. Meanwhile, the peak-to-peak commutation error was controlled within 0.5°. [Conclusion] The commutation correction method based on FWE-QPLL phase extraction can improve the symmetry of current waveforms and enhance the accuracy of sensorless commutation control for high-speed BLDCM.
    5  A Self-Attention-Based Fault Diagnosis Method with Discrete Wavelet Transform for Inter-Turn Short Circuit Faults in Valve Cooling System Main Pump Motors
    Leng Chao ,  Wang Chaofan ,  Zhao Haisen
    2026(11):1156-1165. DOI: 10.12177/emca.2026.244
    [Abstract](3) [HTML](0) [PDF 571.25 K](0)
    Abstract:
    [Objective] The main pump motor of the valve cooling system generally adopts a squirrel-cage asynchronous motor, which is prone to inter-turn short circuit faults during long-term operation. Traditional time-frequency analysis methods struggle to effectively extract and distinguish feature information corresponding to different severity levels of inter-turn short-circuit faults. [Methods] To address this issue, this paper proposed a fault diagnosis method that integrated the discrete wavelet transform (DWT) with the self-attention mechanism. Firstly, inter-phase differentiation was applied to stator three-phase current signals. The channel number was expanded to 6 to incorporate inter-phase unbalance characteristics. Then, the DWT was employed to perform multi-scale frequency-band decomposition on the signals, and linear interpolation was adopted to unify all sub-bands into equal-length Token sequences. Finally, the Token sequences were fed into a Transformer encoder, in which global feature interaction was realized through the multi-head self-attention mechanism, and the classification Token was fused with global average pooling to complete the classification task. Compared with traditional time-frequency analysis methods, the proposed method directly took the 1D frequency bands as input, thereby avoiding the information compression and distortion incurred during 2D image transformation. During the model training and evaluation stages, a 5-fold cross-validation was adopted to eliminate the randomness caused by a single data split and rigorously validate the generalization capability of the proposed method. [Results] To verify the effectiveness of the proposed DWT-Transformer model, it was compared with two models that combine the continuous wavelet transform (CWT) with the vision Transformer (ViT). The experimental results showed that under 5-fold cross-validation, the average test accuracy of the proposed DWT-Transformer model reached 97.57%, which was superior to the two CWT-ViT models. [Conclusion] The combination of DWT multi-scale frequency band decomposition and self-attention mechanism has certain feasibility and effectiveness in the fault diagnosis of motor inter-turn short circuit.
    6  Integral Sliding Mode Active Disturbance Rejection Speed Control forPMSM with NLESO-Based Active Damping Compensation
    Yu Mengtao ,  Ren Zhengyun
    2026(11):1166-1180. DOI: 10.12177/emca.2026.236
    [Abstract](4) [HTML](0) [PDF 644.77 K](1)
    Abstract:
    [Objective] Aiming at the problem that the speed control system of permanent magnet synchronous motor (PMSM) tends to suffer from increased overshoot and slow disturbance recovery under the conditions of rapid reference speed variation, load disturbance and parameter perturbation, this paper proposes an active damping integral sliding mode control (ADISMC) method based on the nonlinear extended state observer (NLESO). [Methods] This method equivalented the PMSM speed loop to a first-order system with lumped disturbances. The NLESO was used to online estimate the lumped disturbances and speed variation trend. An active damping term consisting of the speed derivative estimated by the NLESO was introduced into the integral sliding mode surface, so that the controller could adjust the sliding mode dynamics in real time according to the speed variation trend. The speed-loop control law was constructed by combining disturbance feedforward compensation and exponential reaching law. Furthermore, the uniformly ultimately boundedness of the sliding mode variable and speed error was proven under the premise that the disturbance estimation error was bounded. [Results] Comparisons between the proposed method and other speed control algorithms were carried out under the constraints of identical sampling period, current limiting and parameter tuning. The Simulink simulations covered various operating conditions: no-load step response, sudden load change, composite speed reference of low speed and forward-reverse rotation, continuous load with current limitation, single-parameter perturbation and simultaneous multi-parameter perturbation. The simulation results showed that the proposed method achieved smaller overshoot and shorter disturbance recovery time under all test conditions. Experimental verifications were implemented on an embedded platform with the VOFA+ host computer. The experimental results demonstrated that the overshoot of the proposed method was 0.46% under the no-load step operating condition; the speed drop was 24.8 r/min and the recovery time was 15 ms under load disturbance operating condition. [Conclusion] These results verify the effectiveness and practical implementability of the proposed method for PMSM speed control.
    7  Study on the Influence Mechanism of Inter-turn Short Circuit Fault on Performance of Permanent Magnet Synchronous Motors
    Wang Tianyang ,  Li Ming ,  Lun Shuxian
    2026(11):1181-1190. DOI: 10.12177/emca.2026.239
    [Abstract](5) [HTML](0) [PDF 508.39 K](0)
    Abstract:
    [Objective] Permanent magnet synchronous motor (PMSM) is prone to stator winding inter-turn short circuit faults under complex operating conditions, which may further trigger permanent magnet demagnetization and severely degrade the motor performance. This paper aims to reveal the influence law of inter-turn short circuit fault on the electromagnetic field and performance parameters of PMSM considering demagnetization effects. [Methods] A 1.5 kW PMSM was taken as the research object, and an external circuit-finite element coupled calculation model was established. The inter-turn short circuit parameters were introduced into the external circuit to build the faulty winding model. By solving the distribution of short circuit current, the influence of short circuit fault on the demagnetization degree of permanent magnets was analyzed. On this basis, the variation laws of performance parameters including air gap flux density, induced electromotive force, motor losses, electromagnetic torque and efficiency were investigated. [Results] With the increase of short circuited turns, the local demagnetization effect of permanent magnets induced by short circuit current was significantly aggravated, and the air gap flux density waveform was distorted, with its fundamental amplitude decreasing from 0.81 T to 0.74 T. Meanwhile, the unbalance of stator current deteriorated continuously. The copper loss rose from 42.47 W to 356.75 W, while the iron loss decreased from 30.06 W to 25.82 W, leading to an overall increase in total loss. The electromagnetic torque increased from 1.61 N·m to 2.24 N·m, and the motor full-load efficiency dropped from 92.77% to 82.56%. [Conclusion] Inter turn short circuits induce permanent magnet demagnetization via short circuit current, which is a key factor causing the distortion of electromagnetic field distribution and performance degradation of PMSM. As the fault severity increases, the coupling effect between demagnetization and current distortion is continuously strengthened, eventually resulting in increased losses, torque attenuation and reduced efficiency of the PMSM.
    8  SRM Torque Ripple Control Based on Error Compensation and Dynamic Adjustment of Switching Angle and Voltage
    Jiang Jianquan ,  Cai Hui
    2026(11):1191-1204. DOI: 10.12177/emca.2026.235
    [Abstract](1) [HTML](0) [PDF 756.35 K](0)
    Abstract:
    [Objective] Switched reluctance motor (SRM) possesses an inherent large torque ripple owing to its unique doubly salient structure, which hinders its deployment in high-performance applications. For conventional torque sharing function (TSF) control strategy, the decreased inductance variation rate in the late commutation stage degrades torque tracking performance and induces prominent torque ripple. [Methods] To address this issue, this paper designed a compensated TSF based on cross-phase torque error. The steady-state torque tracking error of the outgoing phase at the late commutation stage was taken as a dynamic correction term and superimposed in real time onto the reference torque command of the incoming phase. By utilizing the high control gain of the incoming phase in the inductance rising region, precise compensation of commutation error was achieved, so as to improve the torque tracking accuracy throughout the commutation process. Furthermore, aiming at the insufficient current eatablishment/decay time as well as aggravated negative torque induced by magnetic saturation under high speed and heavy load conditions, a coordinated regulation strategy of turn-on/turn-off angles and winding voltage was further proposed within the framework of the compensated TSF. The turn-on and turn-off angles were dynamically optimized according to the rotational speed to reserve sufficient time for current establishment and decay. Combined with the Cuk converter and the conventional asymmetric half-bridge topology, the direct current bus voltage was dynamically boosted with the operating speed to accelerate the winding demagnetization process under high-speed conditions and effectively suppressed braking negative torque. [Results] To verify the effectiveness of the proposed strategy, a 6/4-pole SRM simulation model was built in Matlab/Simulink. Comparative simulations between the proposed novel TSF and the conventional TSF were carried out under three typical operating conditions: medium-speed light-load, high-speed light-load and high-speed heavy-load, and tests were performed on the experimental platform. The results showed that compared with the conventional TSF, the proposed novel TSF reduced the torque ripple coefficients from 5.63%, 12.99% and 13.45% to 2.86%, 3.96% and 3.69%, with reductions of 2.77%, 9.03% and 9.76%, respectively. Under high-speed light-load and high-speed heavy-load conditions, the amplitudes of negative torque decreased from 0.600 N·m and 1.127 N·m to 0.096 N·m and 0.219 N·m. [Conclusion] The proposed novel TSF control strategy can effectively suppress torque ripple and significantly reduce negative torque under various operating conditions. It can tackle the dual challenges induced by speed and load variations and possesses superior adaptability across the full operating range.
    9  Research on H∞ Robust Control of Magnetic Levitation System for Controllable Excitation Linear Synchronous Motor Based on SMDO and Disturbance Feedforward
    Zhao Heyu ,  Lan Yipeng
    2026(11):1205-1215. DOI: 10.12177/emca.2026.237
    [Abstract](2) [HTML](0) [PDF 509.60 K](0)
    Abstract:
    [Objective] The magnetic levitation system of the controllable excitation linear synchronous motor (CELSM) is susceptible to multiple-source disturbances including parameter perturbations, sudden load variations and end effects during practical operation. Meanwhile, the system exhibits strong nonlinear characteristics, which greatly increases the difficulty of servo control. To improve the feeding accuracy, dynamic response speed and anti-disturbance capability of the system, this paper proposes a composite control strategy integrating sliding mode disturbance observer (SMDO) feedforward compensation and H∞ robust control. [Methods] Firstly, the structure and levitation mechanism of CELSM were analyzed. Within the id=0 vector control scheme, the additional electromagnetic attraction induced by q-axis current was treated as levitation-direction disturbance. A nonlinear state-space model of the magnetic levitation system with model uncertainties and external disturbances was built, and linearization and decoupling were achieved via Taylor expansion at the equilibrium point. Then, a third-order SMDO equipped with an integral sliding surface and adaptive variable-gain reaching law was designed for real-time and high-precision lumped disturbance estimation. Lyapunov stability analysis verified the finite-time convergence of observation errors to the sliding surface. Accordingly, the H∞robust controller with disturbance feedforward compensation was constructed. Finally, comparative simulations of the proposed composite H∞ control, proportional-integral (PI) control and linear active disturbance rejection control (LADRC) were carried out in Matlab under the conditions of start-up, sudden step load and sinusoidal end effect. [Results] The results showed that under the start-up condition, the settling time of the composite H∞ control was only 0.03 s with no overshoot and zero steady-state error, which outperformed PI control (0.07 s) and LADRC (0.05 s). When a step load disturbance of 15 N was suddenly applied, the composite H∞ control could significantly suppress the dynamic drop of the air-gap height. Its recovery time was merely 0.024 s, much faster than PI control (0.18 s) and LADRC (0.03 s), and the chattering of the excitation current was the smallest. Under the sinusoidal end-effect disturbance of 15sin(20πt) N, the composite H∞ control enabled the air-gap height error to remain basically stable without obvious fluctuations. [Conclusion] The proposed composite H∞ control strategy significantly improves the static and dynamic robustness of the magnetic levitation system of the CELSM.
    10  Rapid Identification of Inter-Turn Short Circuits in Annular Linear Induction Pumps Based on Electromagnetic Field Reduced-Order
    Liu Wei ,  Liu Yang ,  Qin Feng ,  Su Hua
    2026(11):1216-1228. DOI: 10.12177/emca.2026.246
    [Abstract](3) [HTML](0) [PDF 813.14 K](0)
    Abstract:
    [Objective] Inter-turn short circuit (ITSC) is a typical fault of the annular linear induction pump (ALIP), which impairs the transport capacity of liquid metal coolant and the heat dissipation performance of fast reactors. To address this issue, this paper proposes an ITSC fault inversion method based on electromagnetic field reduced-order model (ROM) with the particle swarm optimization (PSO) algorithm. [Methods] A prototype sodium-cooled ALIP was taken as the research object, a fault simulation and leakage magnetic field test platform was established. Latin hypercube sampling was adopted to generate sample datasets under various fault conditions. Proper orthogonal decomposition was used to extract the electromagnetic field dominant modes and corresponding mode coefficients. A deep neural network was further combined to establish the nonlinear mapping between operating condition parameters and mode coefficients, and the electromagnetic field ROM of the ALIP was constructed. Taking the sparse magnetic flux measurement data on the pump shell as inputs, the established ROM and the PSO algorithm were utilized to realize the rapid reconstruction and identification of ITSC faults. [Results] The results showed that the maximum relative errors of the ROM-calculated shell leakage magnetic field and core magnetic field against the full-order model (FOM) were 3.9% and 3.5%, respectively, and the computational speed was improved by a factor of 4 447 compared with the FOM. The proposed inversion method could accurately identify ITSC faults, with a single inversion taking only 12 s. [Conclusion] The proposed method provides methodological support for developing digital-twin-oriented ALIP health management systems and facilitates the enhancement of operational reliability for the equipment and new-generation nuclear power systems.

    Current Issue


    Volume , No.

    Table of Contents

    Archive

    You are thevisitor
    沪ICP备16038578号-3
    Electric Machines & Control Application ® 2026
    Supported by:Beijing E-Tiller Technology Development Co., Ltd.

    沪公网安备 31010702006048号